background image

Diesel Generator Set

 

B5.9 Series

100-125 kVA, 80-100 kWe Prime

Specification

Sheet

Latest Technology And Unmatched
performance

n

n

n

n

n

The Cummins

®

B5.9 series rugged engine and world 

class Stamford alternator powered diesel generator
set
Proven technology with mechanical fuel system.
Exhaust after-treatment, in-cylinder solution to meet 
latest Emission norms
Smart aesthetic and superior finish
Compact in size with optimum Power to weight ratio

Environment Friendly Power

n

n

Class defining technology engine is designed to meet 
stringent exhaust emission tests as per revised MoEF 
norms, thus offering environment friendly power
The Cummins

®

 

diesel generator sets are available 

with the lowest noise levels in its range

Lowest Operating Cost And 
Comprehensive Warranty

n

n

n

n

Highly reliable and durable Product
All elements are designed to work together to
maximize efficiency even at part loads, offering the 
advantage of lowest operating costs
250 Hours/ 1 year service interval
Industry acknowledged best-in-class comprehensive 
warranty on the entire package including rubber 
components

Single Source Power Assurance

n

n

n

All the major components – the engine, alternator, 
control system and canopy are designed, 
manufactured and tested by Cummins India
Best and largest customer support network in India, 
capable of providing round-the-clock service and 
spares support
All these things put together, Cummins

®

 

offers you 

SINGLE SOURCE POWER ASSURANCE

background image

Specification Sheet

Diesel Generator Set B5.9 Series

Engine

n

n

n

Cummins B5.9 series, 6 cylinder, In-line 4 stroke, radiator 
Cooled Engine
Well designed air handling system with

      -  

Dry type, heavy 

d

uty, replaceable paper element air 

         

cleaner with restriction indicator 

      -  

Air to air aftercooling

      - 

Optimised turbocharger for increased altitude capabilities

 

Optimised fuel consumption with 

-  Inline fuel pump with mechanical governing

n

n

n

n

n

n

-  Spin on dual fuel filter with water separator

Standard integral set-mounted radiator system, designed 
and tested for 50°C ambient temperatures
Full flow spin on lube oil filter
First fill of lube oil and Coolant
Electrical starter motor with soft start engagement feature 
Battery charging alternator
1 x 12 V DC battery

PS0500 Features

Cummins PowerStart™ PS0500 
control is a microprocessor 
based generator set monitoring 
and control system. This 
control includes an intuitive 
operator interface that allows 
for complete generator set 
control as well as system metering, fault annunciation, 
configuration and diagnostics.

n

n

n

n

n

n

n

n

n

n

n

n

n

Intuitive operator interface which includes LED backlit LCD 
display with tactile feel soft-switches & generator set status 
LED lamps
Remote Start-Stop
Engine Metering: Oil pressure, Engine temperature, Starting
battery voltage, Engine running hours
AC Alternator Metering: L-L Voltage and L-N Voltage, 
Current (phase and total), kVA (phase and total), Frequency.
Engine Protection: Low lube oil pressure, High/Low coolant 
temperature, Battery Over/Under/Weak Volts, Fail to Crank/
Start, Sensor failure, cranking lockout, Low fuel level.
AC Alternator Protection: Over/ Under Voltage, Over/ Under
Frequency, Loss of AC sensing.
Data Logging: Engine hours, Control hours and upto 
5 recent fault codes
Configurable glow plug control
12 Volt DC operation
Sleep mode
Modbus interface (RS485 RTU)
InPower compatible (PC based service tool)
Certifications - meets the requirement of relevant ISO, EN, 
Mil Std. and CE standards

Alternator

n

n

n

n

n

n

n

Stamford UC27 alternator frames from Cummins Generator
Technologies
Brushless type, screen protected, revolving field, 
self excited alternator conforming to IS/IEC 60034-1
3 Phase reconnectable winding with 12 terminals brought 
out for connection
Better motor starting capability
Best in class efficiency
Compact design with sealed bearings for longer life and 
lesser maintenance
Impregnation on all wound components for better 
mechanical strength 

Control Panel

Control panel is manufactured with 14/16 gauge CRCA sheet
and is powder coated for weather-proof and long lasting finish.
The control panel consists of the following parts:

n

PS0500 Controller

n

Aluminum bus bars with suitable capacity with incoming/ 
outgoing terminals

n

Indicating lamps for ‘Load ON’ and ‘Set Running’

n

Instrument fuses duly wired and ferruled

n

MCCB of suitable rating with overload and short circuit 
protections

n

Hospital grade silencer with rain cap suitably optimized to 
meet stringent noise emission standards laid down by 
MoEF / CPCB

Mounting Arrangement

n

n

Engine and alternator are mounted on a common MS 
fabricated base frame with AVM pads
Base frame with integral fuel tank is provided with drain 
plug, air vent, inlet and outlet connection, level indicator 
and provision for cleaning

Optional

n

n

n

n

Engine:

Coolant heater, Oil drain pump, Electronic 

Governing

Alternator:

PMG

Control Panel:

PC1.1, Microprocessor / relay based AMF 

control panel

Others:

Trolley mounted mobile sets

Silencer

n

Hospital grade silencer with rain cap suitably 
optimised to meet stringent noise emission standards 
laid down by MoEF / CPCB

background image

Specification Sheet

Diesel Generator Set B5.9 Series

Acoustic Enclosure

n

n

n

n

Specially designed to meet stringent MoEF/ CPCB norms 
of 75 dBA @ 1mtr at 75% load under free field conditions
The acoustic enclosure is made of CRCA sheets in munsel 
green shade and a structural/ sheet metal base frame 
painted in black
High quality noise absorbant and fire-retardant grade 
acoustic insulation material (P.U. Foam) complying to 
IS 8183
Two point lifting for easy handling at customer site

n

n

n

n

n

n

n

n

 

Designed to have optimum serviceability

Air inlet louvers specially designed to operate at rated load

 

Made on special purpose CNC machines for consistency in

 

quality and workmanship
11 tank pretreatment process and UV resistant powder 
coating of all parts to withstand extreme environment
Use of special hardware for longer life
Flush styling - no projections
Fluid drains for lube oil and fuel
Fuel filling arrangement inside the enclosure

Technical Data

C100D5P

C125D5P

Prime

Prime

100/80

125/100

3  

  3

415 V, 50 Hz

415 V, 50 Hz

0.8 (lagging)

0.8 (lagging)

139

174

Generator Set Specification

Model 
Duty
Power Rating kVA / kWe 
No. of Phases
Output Voltage and Frequency (V and Hz)
Power Factor 
Current (A)
RPM

1500

1500

Cummins

Cummins

6BTAA5.9-G13

6BTAA5.9-G13

159

159

129

15

8

Liquid Cooled (EG Compleat 50:50)
Turbocharged, Charge Air Cooled
6, In-line
102 x 120
16.5:1

Liquid Cooled (EG Compleat 50:50)
Turbocharged, Charge Air Cooled
6, In-line
102 x 120
16.5:1

5.9

5.9

High Speed Diesel

High Speed Diesel

18.4

22.4

24.4

30

.

35

ISO 8528-5 G2

ISO 8528-5 G2

12 V DC Electrical

12 V DC Electrical

CI4+ 15W40

CI4+ 15W40

19.9-14.9

19.9-14.9

21.4

21.4

0.024

0.024

26

26

4  

  4

52

3

52

3

1066 x 725 x 1033 

1066 x 725 x 1033

6  

  6

311

311

Engine specification

Make 
Model 
MoEF Certified Power (hp)
Required Power for Rated kVA (hp)
Cooling 
Aspiration
No. of cylinders 
Bore (mm) x Stroke (mm) 
Compression ratio
Displacement (litre) 
Fuel 
Fuel consumption @75% load with radiator and fan* (litre/hr)
Fuel consumption @100% load with radiator and fan*  (litre/hr)
Performance class of generator set
Starting system 
Lube oil specification 
Lube oil sump capacity, High-Low level (litre) 
Total lubrication system capacity (litre) 
Lube oil consumption @ full load** (litre/hr)
Total coolant capacity (litre) 
Exhaust pipe size (inch)
Total wet weight (Engine+Radiator)## (kg)
Length x Width x Height (Engine) (mm)
Mean Piston speed (m/s)
Combustion air intake @100% load (±5%) (cfm)
Exhaust Temperature (°C)

553

553

Alternator specification

Make 
Alternator Frame
Enclosure
Voltage regulation (Max.) 
Class of Insulation 
Winding Pitch
Stator Winding
Rotor
Waveform distortion/ Total Harmonic Distortion 

Maximum Unbalanced Load across phases#
Telephonic Harmonic factor

Stamford (CGT)
UCI274C
IP 23
±1%
H Class
2/3
Double layer lap
Dynamically Balanced
No load < 1.5 %, 
Non distorting balanced linear load < 5 %       
less than or equal to 25%
< 2%

Stamford (CGT)
UCI274V
IP 23
±1%
H Class
2/3
Double layer lap
Dynamically Balanced
No load < 1.5 %, 
Non distorting balanced linear load < 5 %
less than or equal to 25%
< 2%

* Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to IS:1460. Fuel consumption tolerance is +5%
**Oil consumption data is based on oil having specific gravity of 0.89 and meeting CI4+ API categories
# With the condition that none of the phases exceeds its rated current

background image

Cummins India Limited 

Power Generation Business Unit

Cummins India Office Campus

Tower-A, 6

th

 Floor, S. No. 21,  

Balewadi, Pune – 411 045 (India)
Email: cpgindia@cummins.com

 

www.cumminsindia.com

“Our energy working for you.”

© 201

5

 Cummins Power Generation Inc. All rights reserved.

Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.

 

PowerCommand, AmpSentry, InPower and are trademarks of Cummins Power Generation.

 

Other company product or service names may be trademarks or service marks of others.

 

Specifications are subject to change without notice.

PGBU/CIL/0

02/6B5.9 100-125 kVA/ SA/ KG/July 2015

Visit our facebook page at : 
Cummins Power Generation India

Authorised Representative

Cummins Power Generation Offices

Bengaluru:  

Tel.: (080) 2325 9161 / 63, 2325 9165 / 67
Fax: (080) 2325 9164

Chandigarh:  

Tel.: (0172) 224 0371-73
Fax: (0172) 224 0372

Chennai:  

Tel.: (044) 2446 8110 / 2446 8113
Fax: (044) 2491 1120

Gurgaon:  

Tel.: (0124) 391 0900-01
Fax : (0124) 391 0916

Hyderabad:  

Tel.: (040) 2340 9970 / 2340 9980
Fax. (040) 2340 9990

Jaipur:  

Tel.: (0141) 236 4944
Fax: (0141) 403 8794

Kolkata:  

Tel.: (033) 2287 8065 / 2287 2481
Fax: (033) 2290 3839

Lucknow:  

Tel.: (0522) 230 5049 / 230 5059
Fax: (0522) 230 5035

Mohali:  

Tel.: (0172) 224 0371 / 72 / 73
Fax: (0172) 224 0371 / 72 / 73

Vadodara:  

Tel.: (0265) 233 0627 / 3053627
Fax: (0265) 234 0623

Diesel Generator Set B5.9 Series

Specification Sheet

Rating Definitions

Prime Power (PRP):
Applicable for supplying power to varying electrical load for
unlimited hours. Prime Power (PRP) is in accordance with ISO
8528. 

Conformance Standards

n

IS/IEC 60034-1

n

IS 1460

n

ISO 8528

n

ISO 3046

n

ISO 9001

n

IS 13018 

Genset Model

Rating (kVA)

Length (mm)

Width (mm)

Height (mm)

Wet Weight

## 

(kg) 

Standard Fuel tank 
Capacity (litre)

C

10

0D5P

100

4000

1150

1850

2200

29

0

C

1

25D5P

125

4000

1150

1850

2200

29

0

#Approximate weight