background image

Diesel Generator Set

 

X1.3 Series

7.5-15 kVA, 6-12 kWe Prime

Latest Technology and Unmatched 

Performance

ƒ

ƒ

The Cummins

®

 X1.3 series rugged engine and world 

class Stamford alternator powered  diesel generator 
set

ƒ

ƒ

Advanced in-cylinder technology to meet latest 
emission norms without any after-treatment device.

ƒ

ƒ

Best in class transient response

ƒ

ƒ

High altitude capabilities

ƒ

ƒ

Smart aesthetic and superior finish

ƒ

ƒ

Compact in size with optimum power to weight ratio

Environment Friendly Power

ƒ

ƒ

Class defining technology engine is designed to meet 
stringent exhaust emission tests as per revised MoEF 
norms, thus offering environment friendly power.

ƒ

ƒ

The Cummins

®

 diesel generator sets are available with 

the lowest noise levels in its range

Lowest Operating Cost and 

Comprehensive Warranty

ƒ

ƒ

Highly reliable and durable product

ƒ

ƒ

All elements are designed to work together to 
maximize efficiency even at part loads, offering the 
advantage of lowest operating costs.

ƒ

ƒ

500 Hours/ 1 year service interval

ƒ

ƒ

Industry acknowledged best-in-class comprehensive 
warranty on the entire package including rubber 
components 

Single Source Power Assurance

ƒ

ƒ

All the major components – the engine, alternator, 
control system and canopy are designed, 
manufactured and tested by Cummins India. 

ƒ

ƒ

Best and largest customer support network in India, 
capable of providing round-the-clock service and 
spares support

ƒ

ƒ

All these things put together, Cummins

®

 offers you 

SINGLE SOURCE POWER ASSURANCE

Specification Sheet

background image

Engine

ƒ

ƒ

Cummins

®

 X1.3 series, 2 cylinder, In-line 4 stroke, radiator 

cooled engine

ƒ

ƒ

Well designed air handling system with

 

— Dry type, Replacable paper element air cleaner with 

restriction indicator 

 

— Air to air aftercooling

 

— Optimised turbocharger for increased altitude 

capabilities

ƒ

ƒ

Best in class fuel economy with  

 

— Inline fuel pump with A1 class mechanical governing

 

— Spin on fuel filter

ƒ

ƒ

Standard integral set-mounted radiator system, designed 
and tested for 50°C ambient temperatures

ƒ

ƒ

Full flow spin on lube oil filter

ƒ

ƒ

First fill of lube oil and coolant

ƒ

ƒ

Electrical starter motor with soft start engagement feature 

ƒ

ƒ

Battery charging alternator

ƒ

ƒ

1 X 12 V DC battery

Alternator

ƒ

ƒ

Stamford PI0,S0L1,S0L2 and PT0 alternator frames from 
cummins Generator Technologies

ƒ

ƒ

Brushless type, Screen protected, Revolving field, Self 
excited alternator conforming to IS/IEC 60034-1

ƒ

ƒ

Better motor starting capability

ƒ

ƒ

Best in class efficiency

ƒ

ƒ

Compact design with sealed bearings for longer life and 
lesser maintenance

ƒ

ƒ

Impregnation on all wound components for better 
mechanical strength    

Control Panel

Control panel is manufactured with 14/16 gauge CRCA sheet 
and is powder coated for weather-proof and long lasting finish.
The control panel consists of the following parts:

ƒ

ƒ

PS0500 controller

ƒ

ƒ

Aluminum bus bars with suitable capacity with incoming/
outgoing terminals

ƒ

ƒ

Indicating lamps for ‘Load ON’ and ‘Set Running’

ƒ

ƒ

Instrument fuses duly wired and ferruled

ƒ

ƒ

MCCB of suitable rating with overload and short circuit  
protections

PS0500 Features

 
Cummins PowerStart™ 
PS0500- control is a 
microprocessor based 
generator set monitoring
and control system. This
control includes an intuitive
operator interface that allows
for complete generator set
control as well as system metering, fault annunciation,
configuration and diagnostics.

ƒ

ƒ

Intuitive operator interface which includes LED backlit LCD 
display with tactile feel soft-switches & generator set status

ƒ

ƒ

LED lamps

ƒ

ƒ

Remote Start-Stop

ƒ

ƒ

Engine Metering: Oil pressure, Engine temperature, Starting 
battery voltage, Engine running hours

ƒ

ƒ

AC Alternator Metering: L-L Voltage and L-N Voltage,

ƒ

ƒ

Current (phase and total), kVA (phase and total), Frequency.

ƒ

ƒ

Engine Protection: Low lube oil pressure, High/Low coolant 
temperature, Battery Over/Under/Weak Volts, Fail to Crank/ 
Start, Sensor failure, cranking lockout, Low fuel level.

ƒ

ƒ

AC Alternator Protection: Over/ Under Voltage, Over/ Under 
Frequency, Loss of AC sensing. 

ƒ

ƒ

Data Logging: Engine hours, Control hours and upto 5 
recent fault codes

ƒ

ƒ

Configurable glow plug control

ƒ

ƒ

12 Volt DC operation

ƒ

ƒ

Sleep mode

ƒ

ƒ

Modbus interface (RS485 RTU)

ƒ

ƒ

InPower compatible (PC based service tool)

ƒ

ƒ

Certifications - meets the requirement of relevant ISO, EN, 
Mil Std. and CE standards

ƒ

ƒ

Hospital grade silencer with rain cap suitably optimized to 
meet stringent noise emission standards laid down by  
MoEF / CPCB

Silencer

ƒ

ƒ

Critical grade silencer suitably optimized to meet stringent 
sound emission standards laid down by MoEF / CPCB 

Mounting Arrangement

ƒ

ƒ

Engine and alternator are mounted on a common MS 
fabricated base frame with AVM pads.

ƒ

ƒ

Base frame with integral fuel tank is provided with drain 
plug, air vent, inlet and outlet connection, level indicator and 
provision for cleaning

Optional

ƒ

ƒ

Engine: 

Coolant heater, Oil drain pump, Heavy duty air 

cleaner, Electronic governing

ƒ

ƒ

Control Panel:

 Microprocessor / relay based AMF control 

panel

ƒ

ƒ

Others: 

Trolley mounted mobile sets

Diesel Generator Set X1.3 Series

Specification Sheet

background image

Acoustic Enclosure

ƒ

ƒ

Specially designed to meet stringent MoEF/ CPCB norms of 
75 dBA @ 1mtr at 75% load under free field conditions

ƒ

ƒ

The acoustic enclosure is made of CRCA sheets in munsel 
green shade and a structural/ sheet metal base frame 
painted in black.

ƒ

ƒ

High quality noise absorbant and fire-retardant grade 
acoustic Insulation material (P.U. Foam) complying to IS 
8183

ƒ

ƒ

Two point lifting for easy handling at customer site

ƒ

ƒ

Designed to have optimum serviceability

ƒ

ƒ

Air inlet louvers specially designed to operate at rated load

ƒ

ƒ

Made on special purpose CNC machines for consistency in 
quality and workmanship

ƒ

ƒ

11 tank pretreatment process and UV resistant Powder 
Coating of all parts to withstand extreme environment

ƒ

ƒ

Use of special hardware for longer life

ƒ

ƒ

Flush styling - no projections

ƒ

ƒ

Fluid drains for lube oil and fuel

ƒ

ƒ

Fuel filling arrangement inside the enclosure

* Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to IS:1460. Fuel consumption tolerance is +5% 

With the condition that none of the phases exceeds its rated current

Technical Data

Generator set specification

Model 

C7.5D5P

C10D5P

C15D5P

Duty

Prime

Prime

Prime

Power Rating kVA / kWe 

7.5/6

10/8

15/12

No. of Phases

3 Phase 

1 Phase

3 Phase 

1 Phase

3 Phase 

1 Phase

Output Voltage (V)

415

230

415

230

415

230

Power Factor 

0.8 (lagging)

0.8 (lagging)

0.8 (lagging)

Current (3 phase/ 1 phase) (A)

11

33

14

44

21

65

Frequency (Hz) and RPM 

50 Hz, 1500 RPM

50 Hz, 1500 RPM

50 Hz, 1500 RPM

Engine Specification

Make 

Cummins

®

Cummins

®

Cummins

®

Model 

X1.3TAA-G1

X1.3TAA-G1

X1.3TAA-G1

MoEF Certified Power (bhp)

23

23

23

Required Power for Rated kVA (bhp)

12

15

21

Cooling 

Liquid Cooled (EG 

Compleat 50:50)

Liquid Cooled (EG 

Compleat 50:50)

Liquid Cooled (EG 

Compleat 50:50)

Aspiration

Turbocharged, Charge Air 

Cooled

Turbocharged, Charge Air 

Cooled

Turbocharged, Charge Air 

Cooled

No. of cylinders 

2, In-line

2, In-line

2, In-line

Bore (mm) x Stroke (mm) 

95 x 91

95 x 91

95 x 91

Compression ratio

18.3:1

18.3:1

18.3:1

Displacement (litre) 

1.29

1.29

1.29

Fuel 

High Speed Diesel

High Speed Diesel

High Speed Diesel

Fuel consumption @75% load with radiator and fan* 

(litre/hr)

2.04

2.27

2.49

2.63

3.28

3.46

Fuel consumption @100% load with radiator and fan* 

(litre/hr)

2.49

2.75

3.08

3.36

4.27

4.47

Performance class of generator set

ISO 8528-5 G2

ISO 8528-5 G2

ISO 8528-5 G2

Starting system 

12 V DC Electrical

12 V DC Electrical

12 V DC Electrical

Lube oil specification 

CH4 15W40

CH4 15W40

CH4 15W40

Lube oil sump capacity, High-Low level (litre) 

4 - 3

4 - 3

4 - 3

Total lubrication system capacity (litre) 

4.5

4.5

4.5

Total coolant capacity (litre) 

5.5

5.5

5.5

Exhaust pipe size (inch)

1.5

1.5

2

Total wet weight (Engine+Radiator)

##

 (kg)

180

180

180

Length x Width x Height (Engine) (mm)

481 x 715 x 662

481 x 715 x 662

481 x 715 x 662

Mean Piston speed (m/s)

4.6

4.6

4.6

Combustion air intake @100% load (±5%) (cfm)

61

61

61

Exhaust Temperature (°C)

346

346

346

Alternator Specification

Make 

Stamford (CGT)

Stamford (CGT)

Stamford (CGT)

Alternator frame

PI044D

PT044F

PI044E

PT044G

S0L1P1

S0L2 K1

Enclosure

IP23

IP23

IP23

Voltage regulation (Max.) 

±1%

±1%

±1%

Class of Insulation 

H Class

H Class

H Class

Winding Pitch

2/3 

2/3 

2/3 

Stator Winding

Double layer lap

Double layer lap

Double layer lap

Rotor

Dynamically Balanced

Dynamically Balanced

Dynamically Balanced No

Waveform distortion/ Total Harmonic Distortion 

No load < 1.5 %, Non 

distorting balanced linear 

load < 5 %

No load < 1.5 %, Non 

distorting balanced linear 

load < 5 %

No load < 1.5 %, Non 

distorting balanced linear 

load < 5 %

Maximum Unbalanced Load across phases

#

less than or equal to 25%

less than or equal to 25%

less than or equal to 25%

Telephonic Harmonic factor

< 2%

< 2%

< 2%

Diesel Generator Set X1.3 Series

Specification Sheet

background image

Visit our facebook page at : 
Cummins Power Generation India

Cummins India Limited 

Power Systems Business

Cummins India Office Campus

Tower-A, 8

th

 Floor, S. No. 21,  

Balewadi, Pune – 411 045 (India)

Email: cpgindia@cummins.com

www.cumminsindia.com

Typical Enclosed Genset Dimensions

Genset  
Model

Rating  
(kVA)

Length  
(mm)

Width  
(mm)

Height  
(mm)

Wet Weight

##

 

(kg)

Standard Fuel tank 
Capacity (litre)

C7.5D5P

7.5

1460

940

915

600

49

C10D5P

10

1460

940

915

600

49

C15D5P

15

1600

940

1100

640

62

##

 Approximate Weight

Rating Definitions

Prime Power (PRP):

Applicable for supplying power to varying electrical load for 
unlimited hours. Prime Power (PRP) is in accordance with ISO 
8528. 

Conformance Standards

ƒ

 

IS/IEC 60034-1 

ƒ

 

IS 1460 

ƒ

 

ISO 8528

ƒ

 

ISO 3046 

ƒ

 

ISO 9001 

ƒ

 

IS 13018

Authorised Representative

Cummins Power Systems Offices

Bengaluru:  

Tel.: (080) 2325 9161 / 63, 2325 9165 / 67

 

Fax: (080) 2325 9164

Chandigarh:  

Tel.: (0172) 224 0371-73

 

Fax: (0172) 224 0372

Chennai:  

Tel.: (044) 2446 8110 / 2446 8113

 

Fax: (044) 2491 1120

Gurgaon:  

Tel.: (0124) 391 0900-01

 

Fax : (0124) 391 0916

Hyderabad:  

Tel.: (040) 2340 9970 / 2340 9980

 

Fax. (040) 2340 9990

Jaipur:  

Tel.: (0141) 236 4944

 

Fax: (0141) 403 8794

Kolkata:  

Tel.: (033) 2287 8065 / 2287 2481

 

Fax: (033) 2290 3839

Lucknow:  

Tel.: (0522) 230 5049 / 230 5059

 

Fax: (0522) 230 5035

Mohali:  

Tel.: (0172) 224 0371 / 72 / 73

 

Fax: (0172) 224 0371 / 72 / 73

Vadodara:  

Tel.: (0265) 233 0627 / 3053627

 

Fax: (0265) 234 0623

Visit our facebook page at : 
Cummins Power Generation India

“Our energy working for you.”

 

Cummins is registered trademarks of Cummins Inc.
Specifi cations are subject to change without notice.
PSBU/001/X1.3/HD/MP/Revision-1 (10-2017)

Diesel Generator Set X1.3 Series

Specification Sheet