background image

Diesel Generator Set

 

QSK60 Series

2000-2250 kVA Prime

Reliable and durable

Cummins

®

 ‘QSK60 series’ (Quantum leap in product 

technology) diesel engine with strong regrindable 
crankshaft, high strength connecting rod, high pressure 
injection full authority electronic fuel system, 2 pump 2 
loop coolant system. ‘QSK60 series’ generating sets 
are more reliable and durable. Engines have clocked 
millions of hours operating in some of the world’s most 
demanding conditions. Current engines are regularly 
upgraded with new technologies for better performance 
and economy. The ultimate proof of superior performance 
and reliability is the fact that Cummins

®

 manufactures 

these engines in India.

Unmatched Warranty

Cummins

®

 ‘QSK60 series’ diesel engine generating sets 

are a truly cost effective solution to long term power need 
backed by industry best, 2 years / 5000 hrs warranty, 
for the entire generating set. With superior experience 
in technology , design capability, commitment, reliability 
and quality we offer an unmatched 5 years or 5000 
hours (including above 2 years) warranty coverage on 5 
critical components (5C) of the engine – Cylinder Head, 
Camshaft, Crankshaft, Cylinder Block, Connecting Rod 
against manufacturing defect ( 5C warranty is offered only 
for India source product.

Cummins Advantage

Special features of Cummins

®

 ‘QSK60 series’ engines 

like full authority electronic injection, low temperature 
aftercooler, optimised turbocharging and precision 
injection timing make these engines the ultimate in 
exceptional fuel effi ciency all across the operating range.

Single Source Power Assurance

Design, manufacture and testing of engine, alternator 
and other accessories is done by Cummins Group of 
companies for optimum performance and is backed by a 
countrywide product the entire package.

Standard Scope

Engine:

 Cummins

®

 ‘QSK60 series’ full authority 

electronic injection, water cooled engine, 16 cylinder, 4 
stroke, rated at 1500 RPM, conforming to ISO 3046 /IS 
13018 has the following specifi cations:

ƒ

ƒ

Cummins Full Authority electronics

ƒ

ƒ

Cummins HPI injectors

ƒ

ƒ

Cummins turbocharger, pulse tuned exhaust manifold, 
stainless steel exhaust fl exible connections (4 Turbos)

ƒ

ƒ

Radiator or heat exchanger, coolant inhibitor

ƒ

ƒ

Plate type lube oil cooler

ƒ

ƒ

Outboard aftercoolers

ƒ

ƒ

Full fl ow paper element fi lters - fuel, lube oil and by-
pass

ƒ

ƒ

Dry type replaceable paper element air cleaner with 
restriction indicator

ƒ

ƒ

Flywheel housing & fl ywheel to suit single bearing 
alternator

ƒ

ƒ

Starting motor – Electric

ƒ

ƒ

Battery charging alternator

ƒ

ƒ

Cummins PowerCommand

®

 microprocessor based 

genset controller

ƒ

ƒ

First fi ll lube oil

Alternator:

 Stamford brushless alternator

ƒ

ƒ

Seperately excited, self-regulated

ƒ

ƒ

Salient pole revolving fi eld

ƒ

ƒ

Single / double bearing

ƒ

ƒ

VPI epoxy impregnated insulation technology

ƒ

ƒ

Re-greasable deep groove Single bearing

ƒ

ƒ

Excitation - PMG based brushless

ƒ

ƒ

Space heaters, RTD/BTD - (without scanner).

Accessories:

ƒ

Silencer suitably optimized to reduce noise

ƒ

Sturdy base rail

ƒ

990 ltrs. free standing fuel tank

ƒ

Batteries with connecting leads and terminals

background image

Optionals

ƒ

ƒ

Engine: 

Lube oil / Coolant heater with thermostatic switch, 

Air StarterAlternator: PMG

ƒ

ƒ

Alternator: 

Double Bearing

ƒ

ƒ

Control Pane

l

:

AMF control panel, Battery charger, Remote/

Auto start panel, Auto/Manual synchronizing panel, 
Audio/Visual annunciation for faults

ƒ

ƒ

Others: 

398 lts. oil pan for extended oil change interval for 

2000 / 2250 kVA

Control System - PCC3201

The PowerCommand™ 3201 Control is a microprocessor 
based generator set monitoring, and control system.

The control provides an operator interface to the genset, 
digital voltage regulation, digital governing and generator set 
protective functions.

The PowerCommand™ 3201 generator set control is suitable 
for use on a wide range of generator sets in nonparalleling and 
paralleling applications.

The PowerCommand™ Control can be confi gured for any 
frequency, voltage and power connection confi guration from 
120 to13,800 VAC for for 50Hz or 60Hz operation.

Power for the control is derived from the generator set starting 
batteries. The control functions over a voltage range from 
8VDC to 35VDC.     

Major Features

ƒ

ƒ

Digital Full Authority Electronic Engine Controls for Cummins 
HPI-PT fuel systems.

ƒ

ƒ

Digital Voltage Regulation with 3-phase sensing. 

ƒ

ƒ

AmpSentry™ Protection for true alternator overcurrent 
protection.

ƒ

ƒ

Analog and Digital AC Output Metering.

ƒ

ƒ

Battery Monitoring System to sense and warn against a 
weak battery condition.

ƒ

ƒ

Digital Alarm and Status Message Display.

ƒ

ƒ

Generator set Monitoring: Displays status of all critical 
engine and alternator generator set functions.

ƒ

ƒ

Smart Starting Control System: Integrated fuel ramping to 
limit black smoke and frequency overshoot.

ƒ

ƒ

Advanced Serviceability using InPower, a PC-based 
software service tool.

ƒ

ƒ

Control Panel Enclosure - IP-52

Control System

Includes all functions to locally or remotely start and stop, and 
protect the generator set. 

Control Switch - RUN/OFF/AUTO

ƒ

ƒ

OFF Mode - the generator set is shut down and cannot be 
started.

ƒ

ƒ

RUN mode the generator set will execute its start sequence.

ƒ

ƒ

AUTO mode, the generator set can be started with a start 
signal from a remote device

LED Indicating Lamps - 

includes LED indicating 

lamps for the following functions:

ƒ

ƒ

Not-in-auto mode

ƒ

ƒ

Common wiring

ƒ

ƒ

Shutdown

ƒ

ƒ

Remote start command

ƒ

ƒ

Panel lamps and switch.

ƒ

ƒ

Operator panel can be illuminated by a series of high 
intensity LED Lamps

ƒ

ƒ

Fault Reset Switch. Allows the operator to reset the control 
after a warning or shutdown condition.

ƒ

ƒ

Emergency Stop Switch. Immediate shut down of the 
generator set on operation.

Base Engine Protection:

ƒ

ƒ

Overspeed shutdown

ƒ

ƒ

Low Oil Pressure Warning / Shutdown

ƒ

ƒ

High Engine Temperature Warning / Shutdown

ƒ

ƒ

Underspeed / Sensor Fail Shutdown

ƒ

ƒ

Fail to Start / Fail to Crank

ƒ

ƒ

Low / high battery voltage

Optionals

ƒ

ƒ

Remote monitoring

ƒ

ƒ

Modbus Convertor

ƒ

ƒ

Extendable I/O modules

ƒ

ƒ

Network Annunciators

QSK60 2000-2250 kVA Prime

Specifi cation Sheet

PCC 3201

background image

Technical Data

Generator set specifications

Model 

C2000 D5 P

C2250 D5 P

Prime Power Rating kVA

2000

2250

Output Voltage and Frequency 

415V/ *3.3/ *6.6/ 11KV - 50Hz 

415V/ *3.3/ *6.6/ 11KV - 50Hz

Power Factor

0.8 (lag)

0.8 (lag)

No. of phases 

3 phase 

3 phase

Engine specifications

Make 

Cummins

®

Cummins

®

Model 

QSK 60 G4 

QSK 60 G8

No. of cylinders 

16 

16

Aspiration 

Turbocharged - LTA Aftercooled 

Turbocharged - LTA Aftercooled

Bore x Stroke 

159 mm x 190 mm 

159 mm x 190 mm

Displacement 

60.2 ltrs 

60.2 ltrs

Output - Prime 

2319 bhp (1730 kWm) 

2603 bhp (1942 kWm)

Fuel consumption @ 75% load with Rad/HE 

291/281 ltr/hr 

331/321 ltr/hr

Fuel consumption @ 100% load with Rad/HE 390/380 ltr/hr 

390/380 ltr/hr

441/430 ltr/hr

Total wet weight ( engine + radiator) 

9904 kg 

9904 kg

Length x Width x Height (engine) 

2780 x 1591 x 1960 mm 

2780 x 1591 x 1960 mm

Compression Ratio 

14.5:1 

14.5:1

Piston Speed 

9.5 m/s 

9.5 m/s

Governor / Class 

Electronic / A1 

Electronic / A1

Lubricating oil sytem capacity 

280/398 ltrs 

398 ltrs

Coolant capacity (engine + radiator) 

621 ltrs 

621 ltrs

Combustion air intake @ 100% load (+/- 5%) 

136 m3/min 

156 m3/min

Exhaust Temperature 

430

 o

485 

o

C

Alternator specifications

Make 

Stamford-LT 

Stamford-HT 

Stamford-LT 

Stamford-HT

Frame size / Model No. 

PI734F 

HVSI804R 

PI734H 

HVSI804R

Voltage Regulation 

± 0.5% 

± 0.5% 

± 0.5% 

± 0.5%

Insulation 

Class H 

Class F 

Class H 

Class F

Standard Enclosure 

IP 23 

IP 23 

IP 23 

IP 23

Winding Pitch 

2 / 3 Pitch 

2 / 3 Pitch 

2 / 3 Pitch 

2 / 3 Pitch

Stator Winding 

Double layer 

lap,form wound 

Double layer lap, 

form wound 

Double layer lap, 

form wound 

Double layerlap, 

form wound

Rotor Dynamically balanced with grade 2.5

Dynamically 

balanced with 

grade 2.5 

Dynamically 

balanced with 

grade 2.5 

Dynamically 

balanced with 

grade 2.5 

Wave form distortion 

No load < 1.8 

%, non distorting 

balanced linear 

load < 5 % 

No load < 1.5 

%, non distorting 

balanced linear 

load < 3 %

No load < 1.8 

%, non distorting 

balanced linear 

load < 5 %

No load < 1.5 

%, non distorting 

balanced linear 

load < 5 %

Total Harmonic Factor 

Better than 2% 

Better than 2% 

Better than 2% 

Better than 2%

* Refer to Factory for 3.3/*6.6 KV & Alternator frame

Conformance standards

IS/IEC 60034-1, BS 5000, IS 1460, ISO 8528, IS 13018, ISO 3046, ISO 9001 

Rating definitions

Prime Power (PRP):

Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten
percent overload capability is available in accordance with ISO 3046 and IS 13018.

ƒ

ƒ

Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to IS:1460

ƒ

ƒ

Fuel consumption tolerance is +5%

QSK60 2000-2250 kVA Prime

Specification Sheet

background image

Cummins India Limited 

Power Systems Business

Cummins India Offi ce Campus

Tower-A, 8

th

 Floor, S. No. 21, 

Balewadi, Pune – 411 045 (India)

Email: cpgindia@cummins.com

www.cumminsindia.com

“Our energy working for you.”

 

Cummins is registered trademarks of Cummins Inc.
Specifi  cations are subject to change without notice.
PSBU/022/QSK 60-2000-2250 kVA//HD/MP/Revision-1 (11/2017)

Visit our facebook page at :
Cummins Power Generation India

Typical Diesel Genset Dimensions*

Genset Model 

RatingRating 
(kVA) 

Length (mm)  Width (mm) 

Height (mm) 

Weight (kgs.) 
(Wet)

Std. Fuel Tank Capacity 
(Ltrs - External)

C2000D5P 

2000 kVA 

5950 

2594 

3304 

17333 

990

C2250D5P 

2250 kVA 

6175 

2494 

3115 

16546 

990

Authorised Representative

Cummins Power System Offi ces

Bengaluru:  

Tel.: (080) 2325 9161 / 63, 2325 9165 / 67

 

Fax: (080) 2325 9164

Chandigarh:  

Tel.: (0172) 224 0371-73

 

Fax: (0172) 224 0372

Chennai:  

Tel.: (044) 2446 8110 / 2446 8113

 

Fax: (044) 2491 1120

Gurgaon:  

Tel.: (0124) 391 0900-01

 

Fax : (0124) 391 0916

Hyderabad:  

Tel.: (040) 2340 9970 / 2340 9980

 

Fax. (040) 2340 9990

Jaipur:  

Tel.: (0141) 236 4944

 

Fax: (0141) 403 8794

Kolkata:  

Tel.: (033) 2287 8065 / 2287 2481

 

Fax: (033) 2290 3839

Lucknow:  

Tel.: (0522) 230 5049 / 230 5059

 

Fax: (0522) 230 5035

Mohali:  

Tel.: (0172) 224 0371 / 72 / 73

 

Fax: (0172) 224 0371 / 72 / 73

Vadodara:  

Tel.: (0265) 233 0627 / 3053627

 

Fax: (0265) 234 0623

Specifi cation Sheet

QSK60 2000-2250 kVA Prime