Diesel Generator Set
QSK60 Series
2000-2250 kVA Prime
Reliable and durable
Cummins
®
‘QSK60 series’ (Quantum leap in product
technology) diesel engine with strong regrindable
crankshaft, high strength connecting rod, high pressure
injection full authority electronic fuel system, 2 pump 2
loop coolant system. ‘QSK60 series’ generating sets
are more reliable and durable. Engines have clocked
millions of hours operating in some of the world’s most
demanding conditions. Current engines are regularly
upgraded with new technologies for better performance
and economy. The ultimate proof of superior performance
and reliability is the fact that Cummins
®
manufactures
these engines in India.
Unmatched Warranty
Cummins
®
‘QSK60 series’ diesel engine generating sets
are a truly cost effective solution to long term power need
backed by industry best, 2 years / 5000 hrs warranty,
for the entire generating set. With superior experience
in technology , design capability, commitment, reliability
and quality we offer an unmatched 5 years or 5000
hours (including above 2 years) warranty coverage on 5
critical components (5C) of the engine – Cylinder Head,
Camshaft, Crankshaft, Cylinder Block, Connecting Rod
against manufacturing defect ( 5C warranty is offered only
for India source product.
Cummins Advantage
Special features of Cummins
®
‘QSK60 series’ engines
like full authority electronic injection, low temperature
aftercooler, optimised turbocharging and precision
injection timing make these engines the ultimate in
exceptional fuel effi ciency all across the operating range.
Single Source Power Assurance
Design, manufacture and testing of engine, alternator
and other accessories is done by Cummins Group of
companies for optimum performance and is backed by a
countrywide product the entire package.
Standard Scope
Engine:
Cummins
®
‘QSK60 series’ full authority
electronic injection, water cooled engine, 16 cylinder, 4
stroke, rated at 1500 RPM, conforming to ISO 3046 /IS
13018 has the following specifi cations:
Cummins Full Authority electronics
Cummins HPI injectors
Cummins turbocharger, pulse tuned exhaust manifold,
stainless steel exhaust fl exible connections (4 Turbos)
Radiator or heat exchanger, coolant inhibitor
Plate type lube oil cooler
Outboard aftercoolers
Full fl ow paper element fi lters - fuel, lube oil and by-
pass
Dry type replaceable paper element air cleaner with
restriction indicator
Flywheel housing & fl ywheel to suit single bearing
alternator
Starting motor – Electric
Battery charging alternator
Cummins PowerCommand
®
microprocessor based
genset controller
First fi ll lube oil
Alternator:
Stamford brushless alternator
Seperately excited, self-regulated
Salient pole revolving fi eld
Single / double bearing
VPI epoxy impregnated insulation technology
Re-greasable deep groove Single bearing
Excitation - PMG based brushless
Space heaters, RTD/BTD - (without scanner).
Accessories:
Silencer suitably optimized to reduce noise
Sturdy base rail
990 ltrs. free standing fuel tank
Batteries with connecting leads and terminals
Optionals
Engine:
Lube oil / Coolant heater with thermostatic switch,
Air StarterAlternator: PMG
Alternator:
Double Bearing
Control Pane
l
:
AMF control panel, Battery charger, Remote/
Auto start panel, Auto/Manual synchronizing panel,
Audio/Visual annunciation for faults
Others:
398 lts. oil pan for extended oil change interval for
2000 / 2250 kVA
Control System - PCC3201
The PowerCommand™ 3201 Control is a microprocessor
based generator set monitoring, and control system.
The control provides an operator interface to the genset,
digital voltage regulation, digital governing and generator set
protective functions.
The PowerCommand™ 3201 generator set control is suitable
for use on a wide range of generator sets in nonparalleling and
paralleling applications.
The PowerCommand™ Control can be confi gured for any
frequency, voltage and power connection confi guration from
120 to13,800 VAC for for 50Hz or 60Hz operation.
Power for the control is derived from the generator set starting
batteries. The control functions over a voltage range from
8VDC to 35VDC.
Major Features
Digital Full Authority Electronic Engine Controls for Cummins
HPI-PT fuel systems.
Digital Voltage Regulation with 3-phase sensing.
AmpSentry™ Protection for true alternator overcurrent
protection.
Analog and Digital AC Output Metering.
Battery Monitoring System to sense and warn against a
weak battery condition.
Digital Alarm and Status Message Display.
Generator set Monitoring: Displays status of all critical
engine and alternator generator set functions.
Smart Starting Control System: Integrated fuel ramping to
limit black smoke and frequency overshoot.
Advanced Serviceability using InPower, a PC-based
software service tool.
Control Panel Enclosure - IP-52
Control System
Includes all functions to locally or remotely start and stop, and
protect the generator set.
Control Switch - RUN/OFF/AUTO
OFF Mode - the generator set is shut down and cannot be
started.
RUN mode the generator set will execute its start sequence.
AUTO mode, the generator set can be started with a start
signal from a remote device
LED Indicating Lamps -
includes LED indicating
lamps for the following functions:
Not-in-auto mode
Common wiring
Shutdown
Remote start command
Panel lamps and switch.
Operator panel can be illuminated by a series of high
intensity LED Lamps
Fault Reset Switch. Allows the operator to reset the control
after a warning or shutdown condition.
Emergency Stop Switch. Immediate shut down of the
generator set on operation.
Base Engine Protection:
Overspeed shutdown
Low Oil Pressure Warning / Shutdown
High Engine Temperature Warning / Shutdown
Underspeed / Sensor Fail Shutdown
Fail to Start / Fail to Crank
Low / high battery voltage
Optionals
Remote monitoring
Modbus Convertor
Extendable I/O modules
Network Annunciators
QSK60 2000-2250 kVA Prime
Specifi cation Sheet
PCC 3201
Technical Data
Generator set specifications
Model
C2000 D5 P
C2250 D5 P
Prime Power Rating kVA
2000
2250
Output Voltage and Frequency
415V/ *3.3/ *6.6/ 11KV - 50Hz
415V/ *3.3/ *6.6/ 11KV - 50Hz
Power Factor
0.8 (lag)
0.8 (lag)
No. of phases
3 phase
3 phase
Engine specifications
Make
Cummins
®
Cummins
®
Model
QSK 60 G4
QSK 60 G8
No. of cylinders
16
16
Aspiration
Turbocharged - LTA Aftercooled
Turbocharged - LTA Aftercooled
Bore x Stroke
159 mm x 190 mm
159 mm x 190 mm
Displacement
60.2 ltrs
60.2 ltrs
Output - Prime
2319 bhp (1730 kWm)
2603 bhp (1942 kWm)
Fuel consumption @ 75% load with Rad/HE
291/281 ltr/hr
331/321 ltr/hr
Fuel consumption @ 100% load with Rad/HE 390/380 ltr/hr
390/380 ltr/hr
441/430 ltr/hr
Total wet weight ( engine + radiator)
9904 kg
9904 kg
Length x Width x Height (engine)
2780 x 1591 x 1960 mm
2780 x 1591 x 1960 mm
Compression Ratio
14.5:1
14.5:1
Piston Speed
9.5 m/s
9.5 m/s
Governor / Class
Electronic / A1
Electronic / A1
Lubricating oil sytem capacity
280/398 ltrs
398 ltrs
Coolant capacity (engine + radiator)
621 ltrs
621 ltrs
Combustion air intake @ 100% load (+/- 5%)
136 m3/min
156 m3/min
Exhaust Temperature
430
o
C
485
o
C
Alternator specifications
Make
Stamford-LT
Stamford-HT
Stamford-LT
Stamford-HT
Frame size / Model No.
PI734F
HVSI804R
PI734H
HVSI804R
Voltage Regulation
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Insulation
Class H
Class F
Class H
Class F
Standard Enclosure
IP 23
IP 23
IP 23
IP 23
Winding Pitch
2 / 3 Pitch
2 / 3 Pitch
2 / 3 Pitch
2 / 3 Pitch
Stator Winding
Double layer
lap,form wound
Double layer lap,
form wound
Double layer lap,
form wound
Double layerlap,
form wound
Rotor Dynamically balanced with grade 2.5
Dynamically
balanced with
grade 2.5
Dynamically
balanced with
grade 2.5
Dynamically
balanced with
grade 2.5
Wave form distortion
No load < 1.8
%, non distorting
balanced linear
load < 5 %
No load < 1.5
%, non distorting
balanced linear
load < 3 %
No load < 1.8
%, non distorting
balanced linear
load < 5 %
No load < 1.5
%, non distorting
balanced linear
load < 5 %
Total Harmonic Factor
Better than 2%
Better than 2%
Better than 2%
Better than 2%
* Refer to Factory for 3.3/*6.6 KV & Alternator frame
Conformance standards
IS/IEC 60034-1, BS 5000, IS 1460, ISO 8528, IS 13018, ISO 3046, ISO 9001
Rating definitions
Prime Power (PRP):
Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten
percent overload capability is available in accordance with ISO 3046 and IS 13018.
Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to IS:1460
Fuel consumption tolerance is +5%
QSK60 2000-2250 kVA Prime
Specification Sheet
Cummins India Limited
Power Systems Business
Cummins India Offi ce Campus
Tower-A, 8
th
Floor, S. No. 21,
Balewadi, Pune – 411 045 (India)
Email: cpgindia@cummins.com
www.cumminsindia.com
“Our energy working for you.”
Cummins is registered trademarks of Cummins Inc.
Specifi cations are subject to change without notice.
PSBU/022/QSK 60-2000-2250 kVA//HD/MP/Revision-1 (11/2017)
Visit our facebook page at :
Cummins Power Generation India
Typical Diesel Genset Dimensions*
Genset Model
RatingRating
(kVA)
Length (mm) Width (mm)
Height (mm)
Weight (kgs.)
(Wet)
Std. Fuel Tank Capacity
(Ltrs - External)
C2000D5P
2000 kVA
5950
2594
3304
17333
990
C2250D5P
2250 kVA
6175
2494
3115
16546
990
Authorised Representative
Cummins Power System Offi ces
Bengaluru:
Tel.: (080) 2325 9161 / 63, 2325 9165 / 67
Fax: (080) 2325 9164
Chandigarh:
Tel.: (0172) 224 0371-73
Fax: (0172) 224 0372
Chennai:
Tel.: (044) 2446 8110 / 2446 8113
Fax: (044) 2491 1120
Gurgaon:
Tel.: (0124) 391 0900-01
Fax : (0124) 391 0916
Hyderabad:
Tel.: (040) 2340 9970 / 2340 9980
Fax. (040) 2340 9990
Jaipur:
Tel.: (0141) 236 4944
Fax: (0141) 403 8794
Kolkata:
Tel.: (033) 2287 8065 / 2287 2481
Fax: (033) 2290 3839
Lucknow:
Tel.: (0522) 230 5049 / 230 5059
Fax: (0522) 230 5035
Mohali:
Tel.: (0172) 224 0371 / 72 / 73
Fax: (0172) 224 0371 / 72 / 73
Vadodara:
Tel.: (0265) 233 0627 / 3053627
Fax: (0265) 234 0623
Specifi cation Sheet
QSK60 2000-2250 kVA Prime